SP-C SIZE
SPI SIZE
SPCF SIZE
SPHE SIZE
SPP SIZE
SPA SIZE
SPU SIZE
SPAH SIZE
SPAC SIZE
SPHP SIZE
SPT SIZE
SPV SIZE
SPSP SIZE
Tel:0086-519-85083311
Fax:0086-519-85083020 International market:
0086-519-85083311Townway
0086-519-85083201 Joy
0086-519-85083209 Amy
0086-519-85083204 Sean
0086-519-85083376 Amanda
0086-519-85083379 Sunnie
0086-519-85083226 Keyway
0086-519-85083392 Sarch
0086-519-85083393 Melody
Fax:0086-519-85083220 National market:
0086-519-83405913
0086-519-85083133
0086-519-85083233
 Assistant water tank  Controller  Magnesium stick  Big water tank
 Pump  Valve and Meter  Tie-in  Vacuum tube and Heat pipe
Valve and Meter
air_vent_valve
connect flexib pipe to connect flexib pipe
connect flexible pipe to maniflod or copper pipe
connect tank Female outlet to flexible pipe
connect tank to flexible pipe
CORRUCON
     
 
pressure controler
temp valve
TPvalve
TWINPIPE1
TWINPIPE2
   
TWINPIPE3
   
Temperature & Pressure Safetly Valves
Operation Instructions
一、Using Method
Temperature and Pressure Relief Valves is suitable for bearing the pressing type solar water heater, gas heater, electric heater , water heater of fuel, water heater of heat pump, sensitive function heater, etc. various kinds of heaters( such as the boiler) and hot water containers .
二、Technical Parameter
·Standard setting: 75,87,100,125,150psi(0.5、0.6、0.7、0.86、1.0MPa)
·Temperature relief: 210℉(99℃)
·Dimensions/Weights

MODEL

Size
in

Import x Export
in

A
in

B
in

D
in

T
in

Weight
Oz(g)

Temp. Steam
Rating BTU/hr

WYA-15

1/2

R1/2xRp1/2

12/3

31/4

11/8

4

8.4(237)

15,000

WYA-20

3/4

R3/4x Rp3/4

12/3

31/4

11/8

4

9.1(258)

100,000


三、Installation
·Temperature and Pressure Relief Valves should be installed on the water heater top or side.The Temperature sensing element must be inmmeresd in the water within the top 6″of the tank.
·The eliminating pipeline should be installed under the relief valve.Its terminal station distance in floor drain should be greater than 6″to make it easily remove and observe water.







四、Safeguard And Maintenance:After installing,water heater users must lift the relief valve handle once at least every year,so as to ensure that unblocked things in the waterway of the relief valve.Before operating handles,please check the elimination pipeline which joining the relief valve,guaranteed that the hot water from the relief valve discharge the proper place,otherwise it may cause the bodily injury.If the handle is lifted,without water flowing out,it proves that the relief valve is invalid.Then it should turn off the water heater immediately and ask pipeline personnel check and repaire.
五、Designed and checked under “ANSI Z21.22”

 
Copyright ©2008 Changzhou Sunpower Solar Water Heater Co.,Ltd.
Add:69# south airport road,luoxi town,high-tech district,Changzhou,Jiangsu   Tel:0086-519-85083311 0086-519-85083206   Fax:0086-519-85083020     [manager]
苏ICP备05038965号